banner

Quick Details

Uses of KDF55 Filter Media:

  1. Reduces chlorine, heavy metals, and scale in water, minimizing maintenance efforts.

  2. Enhances the effectiveness of carbon filters and extends their lifespan.


Working Principle of KDF55 Filter Media:

When used in water, a chemical reaction called redox (reduction-oxidation) occurs. During this reaction, electrons are transferred between molecules. For example, free chlorine is converted into harmless chloride through this reaction and then filtered out. Similarly, heavy metals such as copper, lead, and mercury react and precipitate on the surface of the filter media, effectively removing them from the water.


Use of KDF55 in High-Temperature Water (0-100°C):

KDF55 remains unaffected even in high-temperature water, such as in hot showers. It helps reduce exposure to harmful chlorine during showering.


Backwashing:

  • Backwash flow rate: Should be 2 times the normal flow rate.

  • Backwash duration: Should be 10 minutes or less.

  • Rinsing: Purge and rinse for 3 minutes, at least twice a week.

  • Adjustments: At lower water temperatures, the backwash speed can be reduced; at higher temperatures, a higher speed can be used.


Cleaning:

If the filter media becomes clogged due to long-term lack of backwashing or use, it can be cleaned using hydrochloric acid.

  1. Prepare the acid solution: Dilute concentrated hydrochloric acid in water to achieve a pH greater than 2.5.

  2. Soak the filter media: Pour the acid solution into the filter media and let it soak.

  3. Backwash: Perform a backwash for 20 minutes until the outflowing water is clear and its pH matches the incoming water.


Summary:

KDF55 filter media is highly effective in reducing chlorine, heavy metals, and scale in water. It enhances the performance of carbon filters and is suitable for use in both cold and hot water systems. Regular backwashing and occasional acid cleaning ensure its optimal performance and longevity.




Specification

Item

Standard

Appearance

Golden brown flaky particle

Bulk Density

2.5~2.7g/ cm3

Diameter

5~100 mesh

alloy of copper and zinc Content (%)

99.8~99.9%

 

Heavy metal Test result - safe for life and drinking water treatment

Item

Unit

Test result

Conclusion

Size

-

Blank

Sample 1

Sample 2

OK

chromaticity

-

<5.0

<5.0

<5.0

OK

Appearance

-

-

Golden brown flaky particle

Golden brown flaky particle

OK

PH value

-

7.98

8.08

8.10

OK

Arsenic(As)

mg/L

0.001

0.001

0.001

OK

Cadmium(Cd)

mg/L

<0.00006

<0.000425

<0.000503

OK

Chromium(Cr)

mg/L

<0.004

<0.004

<0.004

OK

Plumbum(Pb)

mg/L

<0.00007

<0.00007

<0.00007

OK

Aluminium(Al)

mg/L

<0.008

<0.008

<0.008

OK

Mercury(Hg)

mg/L

0.001

<0.001

<0.001

OK

Iron(Fe)

mg/L

0.25

<0.005

<0.005

OK

Volatile phenol

mg/L

<0.002

<0.002

<0.002

OK

Chloroform(CHCl3)

ug/L

<0.6

<0.6

<0.6

OK


Application

i.High-Efficiently remove chlorine,pesticides,organic matter,rust,unpleasant taste and odour.

ii.Efficiently kill algae and fungi,control bacteria growth.

iii.Efficiently removes soluble heavy metal ions in water such as Pb2+,Cd2+,Cr6+,As3+,Hg2+,Mn2+,Ni2+,Al3+,Fe3+ etc.

iv.Efficiently remove hydrogen sulfide,calcium and other organic compounds.




<< Previous page

Next page >>

tel 0799-6335986 mob +86-18107991684 mail yuna@chempacking.cn top